Risk Factors and Interpretation of Inconclusive Endoscopic Ultrasound-Guided Fine Needle Aspiration Cytology in the Diagnosis of Solid Pancreatic Lesions

Background: The inconclusive cytological findings of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) remain a major clinical challenge and often lead to treatment delays. Methods: Patients who had undergone EUS-FNA sampling for solid pancreas lesions between 2014 and 2021 were retrospe...

Teljes leírás

Elmentve itt :
Bibliográfiai részletek
Szerzők: Bor Renáta
Vasas Béla
Fábián Anna
Szűcs Mónika
Bősze Zsófia
Bálint Anita
Rutka Mariann
Farkas Klaudia
Tóth Tibor
Resál Tamás
Bacsur Péter
Molnár Tamás
Szepes Zoltán
Dokumentumtípus: Cikk
Megjelent: 2023
Sorozat:DIAGNOSTICS 13 No. 17
Tárgyszavak:
doi:10.3390/diagnostics13172841

mtmt:34129891
Online Access:http://publicatio.bibl.u-szeged.hu/28219
Leíró adatok
Tartalmi kivonat:Background: The inconclusive cytological findings of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) remain a major clinical challenge and often lead to treatment delays. Methods: Patients who had undergone EUS-FNA sampling for solid pancreas lesions between 2014 and 2021 were retrospectively enrolled. The “atypical” and “non-diagnostic” categories of the Papanicolaou Society of Cytopathology System were considered inconclusive and the “negative for malignancy” category of malignancy was suspected clinically. We determined the frequency and predictors of inconclusive cytological finding. Results: A total of 473 first EUS-FNA samples were included, of which 108 cases (22.83%) were inconclusive. Significant increases in the odds of inconclusive cytological findings were observed for lesions with a benign final diagnosis (OR 11.20; 95% CI 6.56–19.54, p < 0.001) as well as with the use of 25 G FNA needles (OR 2.12; 95% CI 1.09–4.01, p = 0.023) compared to 22 G needles. Furthermore, the use of a single EUS-FNA technique compared to the combined use of slow-pull and standard suction techniques (OR 1.70; 95% CI 1.06–2.70, p = 0.027) and less than three punctures per procedure led to an elevation in the risk of inconclusive cytology (OR 2.49; 95% CI 1.49–4.14, p < 0.001). Risk reduction in inconclusive cytology findings was observed in lesions between 2–4 cm (OR 0.40; 95% CI 0.23–0.68, p = 0.001) and >4 cm (OR 0.16; 95% CI 0.08–0.31, p < 0.001) compared to lesions ≤2 cm. Conclusions: The more than two punctures per EUS-FNA sampling with larger-diameter needle (19 G or 22 G) using the slow-pull and standard suction techniques in combination may decrease the probability of inconclusive cytological findings.
Terjedelem/Fizikai jellemzők:16
ISSN:2075-4418