Safety and efficacy of a sirolimus-eluting coronary stent with ultra-thin strut for treatment of atherosclerotic lesions (TALENT)

Supraflex is a sirolimus-eluting stent with a biodegradable polymer coating and ultra-thin struts. We aimed to compare Supraflex with the standard of care, Xience, an everolimus-eluting stent with a durable polymer coating, regarding clinical outcomes with a randomised trial in an all-comer populati...

Teljes leírás

Elmentve itt :
Bibliográfiai részletek
Szerzők: Zaman Azfar
Winter, de Robbert J
Kogame Norihiro
Chang Chun Chin
Modolo Rodrigo
Spitzer Ernest
Tonino Pim
Hofma Sjoerd
Zurakowski Aleksander
Smits Pieter C.
Prokopczuk Janusz
Moreno Raul
Choudhury Anirban
Ungi Imre
Merkely Béla Péter
TALENT trial investigators
Dokumentumtípus: Cikk
Megjelent: 2019
Sorozat:LANCET 393 No. 10175
doi:10.1016/S0140-6736(18)32467-X

mtmt:30609842
Online Access:http://publicatio.bibl.u-szeged.hu/17964
LEADER 03897nab a2200385 i 4500
001 publ17964
005 20200122085813.0
008 200122s2019 hu o 0|| zxx d
022 |a 0140-6736 
024 7 |a 10.1016/S0140-6736(18)32467-X  |2 doi 
024 7 |a 30609842  |2 mtmt 
040 |a SZTE Publicatio Repozitórium  |b hun 
041 |a zxx 
100 1 |a Zaman Azfar 
245 1 0 |a Safety and efficacy of a sirolimus-eluting coronary stent with ultra-thin strut for treatment of atherosclerotic lesions (TALENT)  |h [elektronikus dokumentum] /  |c  Zaman Azfar 
260 |c 2019 
300 |a 987-997 
490 0 |a LANCET  |v 393 No. 10175 
520 3 |a Supraflex is a sirolimus-eluting stent with a biodegradable polymer coating and ultra-thin struts. We aimed to compare Supraflex with the standard of care, Xience, an everolimus-eluting stent with a durable polymer coating, regarding clinical outcomes with a randomised trial in an all-comer population.We did a prospective, randomised, single-blind, multicentre study (TALENT) across 23 centres in Europe (the Netherlands, Poland, the UK, Spain, Bulgaria, Hungary, and Italy). Eligible participants were aged 18 years or older, had one or more coronary artery stenosis of 50% or greater in a native coronary artery, saphenous venous graft, or arterial bypass conduit, and had a reference vessel diameter of 2·25-4·50 mm. Patients underwent percutaneous coronary intervention in an all-comer manner. We randomly assigned patients (1:1) to implantation of either a sirolimus-eluting stent with a biodegradable polymer coating and ultra-thin struts (Supraflex) or an everolimus-eluting stent with a durable polymer coating (Xience). Randomisation was done by local investigators by use of a web-based software with random blocks according to centre. The primary endpoint was a non-inferiority comparison of a device-oriented composite endpoint-cardiac death, target-vessel myocardial infarction, or clinically indicated target lesion revascularisation-between groups at 12 months after the procedure, assessed in an intention-to-treat population. On assumption of 1-year composite endpoint prevalence of 8·3%, a margin of 4·0% was defined for non-inferiority of the Supraflex group compared with the Xience group. This trial is registered with ClinicalTrials.gov, number NCT02870140.Between Oct 21, 2016, and July 3, 2017, 1435 patients with 1046 lesions were randomly assigned to Supraflex, of whom 720 received the index procedure, and 715 patients with 1030 lesions were assigned to Xience, all receiving the index procedure. At 12 months, the primary endpoint had occurred in 35 patients (4·9 %) in the Supraflex group and in 37 patients (5·3%) in the Xience group (absolute difference -0·3% [one-sided 95% upper confidence bound 1·6%], pnon-inferiority<0·0001). Definite or probable stent thrombosis prevalence, a safety indicator, was low in both groups and did not differ between them.The Supraflex stent was non-inferior to the Xience stent for a device-oriented composite clinical endpoint at 12 months in an all-comer population. Supraflex seems a safe and effective alternative drug-eluting stent to other stents in clinical practice.European Cardiovascular Research Institute. 
700 0 2 |a Winter, de Robbert J  |e aut 
700 0 2 |a Kogame Norihiro  |e aut 
700 0 2 |a Chang Chun Chin  |e aut 
700 0 2 |a Modolo Rodrigo  |e aut 
700 0 2 |a Spitzer Ernest  |e aut 
700 0 2 |a Tonino Pim  |e aut 
700 0 2 |a Hofma Sjoerd  |e aut 
700 0 2 |a Zurakowski Aleksander  |e aut 
700 0 2 |a Smits Pieter C.  |e aut 
700 0 2 |a Prokopczuk Janusz  |e aut 
700 0 2 |a Moreno Raul  |e aut 
700 0 2 |a Choudhury Anirban  |e aut 
700 0 2 |a Ungi Imre  |e aut 
700 0 2 |a Merkely Béla Péter  |e aut 
700 0 2 |a TALENT trial investigators  |e aut 
856 4 0 |u http://publicatio.bibl.u-szeged.hu/17964/1/2019_SafetyEfficacy_Ungi.pdf  |z Dokumentum-elérés