Formaldehyde in screen printing indoor

The presence of formaldehyde in air samples has been detected in five screen printing facilities in Novi Sad, Serbia. Air samples were sampled continuously during 4 hours, and concentration levels of formaldehyde was determined by UV-VIS spectrometry at 580 nm. The range of formaldehyde concentratio...

Teljes leírás

Elmentve itt :
Bibliográfiai részletek
Szerzők: Kiurski Jelena
Adamovic S.
Oros Ivana
Krstic Jelena
Adamović Dragan
Testületi szerző: International Symposium on Analytical and Environmental Problems (17.) (2011) (Szeged)
Dokumentumtípus: Könyv része
Megjelent: SZAB Szeged 2012
Sorozat:Proceedings of the International Symposium on Analytical and Environmental Problems 17
Kulcsszavak:Levegőszennyeződés - beltéri - mérés
Tárgyszavak:
Online Access:http://acta.bibl.u-szeged.hu/76420
Leíró adatok
Tartalmi kivonat:The presence of formaldehyde in air samples has been detected in five screen printing facilities in Novi Sad, Serbia. Air samples were sampled continuously during 4 hours, and concentration levels of formaldehyde was determined by UV-VIS spectrometry at 580 nm. The range of formaldehyde concentrations was from 0.413 to 0.836 ppm. Comparison of the detected concentration levels with the permissible exposure limit of 0.75 ppm (the OSHA standard) indicated that the formaldehyde concentration in facility 5 was 1.11 times higher than prescribed value.
Terjedelem/Fizikai jellemzők:189-192
ISBN:978-963-315-066-5