Fibre optic sensor (FOS) is used to measure the concentration of total chlorine in samples of surface water, swimming pool water and leachate from MSW landfill. FOS represents new original method which is based on the color of the sample for measurement ofanalyteconcentration. Color sensor converts...

Teljes leírás

Elmentve itt :
Bibliográfiai részletek
Szerzők: Obrovski Boris
Bajić Jovan
Mihajlović Ivana
Vojinović-Miloradov Mirjana
Batinić Branislav
Živančev Nevena
Živanov Miloaš
Testületi szerző: International Symposium on Analytical and Environmental Problems (22.) (2016) (Szeged)
Dokumentumtípus: Könyv része
Megjelent: 2016
Sorozat:Proceedings of the International Symposium on Analytical and Environmental Problems 22
Kulcsszavak:Analitikai kémia
Online Access:http://acta.bibl.u-szeged.hu/56023
LEADER 02041naa a2200277 i 4500
001 acta56023
005 20220808154855.0
008 181210s2016 hu o 1|| zxx d
020 |a 978-963-306-507-5 
040 |a SZTE Egyetemi Kiadványok Repozitórium  |b hun 
041 |a zxx 
100 1 |a Obrovski Boris 
245 1 0 |a Monitoring of chlorine by new method based on FOS in water bodies  |h [elektronikus dokumentum] /  |c  Obrovski Boris 
260 |c 2016 
300 |a 13-16 
490 0 |a Proceedings of the International Symposium on Analytical and Environmental Problems  |v 22 
520 3 |a Fibre optic sensor (FOS) is used to measure the concentration of total chlorine in samples of surface water, swimming pool water and leachate from MSW landfill. FOS represents new original method which is based on the color of the sample for measurement ofanalyteconcentration. Color sensor converts RGB (Red-Green-Blue) color model to HSV (Hue-Saturation-Value) color model. S and V parameters were used for determination of chlorineconcentrations in selected water bodies. H parameter was used for the calculation of wavelength at which applied sensor measures the concentration of total chlorine. Research was carried out to validate the effectiveness and repeatability of the results obtained with FOS and confirms the capability to use sensor in laboratory controlled conditions. Results obtained with FOS are compared with standard analytical methods (UV-Vis spectrophotometer) to confirm the possibility of using FOS as replacement for standard analytical expensive equipment. 
695 |a Analitikai kémia 
700 0 1 |a Bajić Jovan  |e aut 
700 0 1 |a Mihajlović Ivana  |e aut 
700 0 2 |a Vojinović-Miloradov Mirjana  |e aut 
700 0 2 |a Batinić Branislav  |e aut 
700 0 2 |a Živančev Nevena  |e aut 
700 0 2 |a Živanov Miloaš  |e aut 
710 |a International Symposium on Analytical and Environmental Problems (22.) (2016) (Szeged) 
856 4 0 |u http://acta.bibl.u-szeged.hu/56023/1/proceedings_of_isaep_2016_013-016.pdf  |z Dokumentum-elérés