Anastomotic leak after manual circular stapled left-sided bowel surgery analysis of technology-, disease-, and patient-related factors /

Anastomotic leak rates after colorectal surgery remain high. In most left-sided colon and rectal resection surgeries, a circular stapler is utilized to create the primary bowel anastomosis. However, it remains unclear whether a relationship between circular stapler technology and anastomotic leak in...

Teljes leírás

Elmentve itt :
Bibliográfiai részletek
Szerzők: Kollaborációs szervezet: European Society of Coloproctology (ESCP) Circular Stapled Anast
Kollaborációs szervezet: 2017 European Society of Coloproctology (ESCP) Collaborating Gro
Tong C.
Jamous N.
Schmitz N-D
Ábrahám Szabolcs
Tóth Illés János
Dokumentumtípus: Cikk
Megjelent: 2024
Sorozat:Bjs Open 8 No. 5
Tárgyszavak:
doi:10.1093/bjsopen/zrae089

mtmt:35796066
Online Access:http://publicatio.bibl.u-szeged.hu/37057
LEADER 03226nab a2200289 i 4500
001 publ37057
005 20250623091855.0
008 250623s2024 hu o 000 eng d
022 |a 2474-9842 
024 7 |a 10.1093/bjsopen/zrae089  |2 doi 
024 7 |a 35796066  |2 mtmt 
040 |a SZTE Publicatio Repozitórium  |b hun 
041 |a eng 
100 2 |a Kollaborációs szervezet: European Society of Coloproctology (ESCP) Circular Stapled Anast 
245 1 0 |a Anastomotic leak after manual circular stapled left-sided bowel surgery  |h [elektronikus dokumentum] :  |b analysis of technology-, disease-, and patient-related factors /  |c  Kollaborációs szervezet: European Society of Coloproctology (ESCP) Circular Stapled Anast 
260 |c 2024 
300 |a 8 
490 0 |a Bjs Open  |v 8 No. 5 
520 3 |a Anastomotic leak rates after colorectal surgery remain high. In most left-sided colon and rectal resection surgeries, a circular stapler is utilized to create the primary bowel anastomosis. However, it remains unclear whether a relationship between circular stapler technology and anastomotic leak in left-sided colorectal surgery exists.A post-hoc analysis was conducted using a prospectively collected data set of patients from the 2017 European Society of Coloproctology snapshot audit who underwent elective left-sided resection (left hemicolectomy, sigmoid colectomy, or rectal resection) with a manual circular stapled anastomosis. Rates of anastomotic leak and unplanned intensive care unit stay in association with manual circular stapling were assessed. Patient-, disease-, geographical-, and surgeon-related factors as well as stapler brand were explored using multivariable regression models to identify predictors of adverse outcomes.Across 3305 procedures, 8.0% of patients had an anastomotic leak and 2.1% had an unplanned intensive care unit stay. Independent predictors of anastomotic leak were male sex, minimal-access surgery converted to open surgery, and anastomosis height C11 (lower third rectum) (all P < 0.050). Independent predictors of unplanned intensive care unit stay were minimal-access surgery converted to open surgery and American Society of Anesthesiologists grade IV (all P < 0.050). Stapler device brand was not a predictor of anastomotic leak or unplanned intensive care unit stay in multivariable regression analysis. There were no differences in rates of anastomotic leak and unplanned intensive care unit stay according to stapler head diameter, geographical region, or surgeon experience.In patients undergoing left-sided bowel anastomosis, choice of manual circular stapler, in terms of manufacturer or head diameter, is not associated with rates of anastomotic leak and unplanned intensive care unit stay. 
650 4 |a Klinikai orvostan 
700 0 2 |a Kollaborációs szervezet: 2017 European Society of Coloproctology (ESCP) Collaborating Gro  |e aut 
700 0 2 |a Tong C.  |e aut 
700 0 2 |a Jamous N.  |e aut 
700 0 2 |a Schmitz N-D.  |e aut 
700 0 2 |a Ábrahám Szabolcs  |e aut 
700 0 2 |a Tóth Illés János  |e aut 
856 4 0 |u http://publicatio.bibl.u-szeged.hu/37057/1/TongCAbrahamSzabolcsTothIllesAnastomoticleakaftermanualcircularstapledleft-sidedbowelsurgery.pdf  |z Dokumentum-elérés