With the recent emergence of highly transmissible variants of the novel coronavirus SARS-CoV-2, the demand for N95 respirators is expected to remain high. The extensive use of N95 respirators by the public is susceptible to demand-supply gaps and raises concern about their disposal, threatening the...

Teljes leírás

Elmentve itt :
Bibliográfiai részletek
Szerzők: Sharma Sumit
Wang Fang
Kumar Shubham
Nawal Ruchika R.
Kumar Priya
Yadav Sudha
Szenti Imre
Kukovecz Ákos
Schiller Ulf D.
Rawal Amit
Dokumentumtípus: Cikk
Megjelent: 2022
Sorozat:JOURNAL OF INDUSTRIAL TEXTILES 51 No. Suppl. 5
Tárgyszavak:
doi:10.1177/15280837221082322

mtmt:33457932
Online Access:http://publicatio.bibl.u-szeged.hu/26514
LEADER 02227nab a2200325 i 4500
001 publ26514
005 20230217083957.0
008 230217s2022 hu o 0|| Angol d
022 |a 1528-0837 
024 7 |a 10.1177/15280837221082322  |2 doi 
024 7 |a 33457932  |2 mtmt 
040 |a SZTE Publicatio Repozitórium  |b hun 
041 |a Angol 
100 1 |a Sharma Sumit 
245 1 0 |a Structural and functional integrity of decontaminated N95 respirators  |h [elektronikus dokumentum] :  |b Experimental results /  |c  Sharma Sumit 
260 |c 2022 
300 |a S7999-S8017 
490 0 |a JOURNAL OF INDUSTRIAL TEXTILES  |v 51 No. Suppl. 5 
520 3 |a With the recent emergence of highly transmissible variants of the novel coronavirus SARS-CoV-2, the demand for N95 respirators is expected to remain high. The extensive use of N95 respirators by the public is susceptible to demand-supply gaps and raises concern about their disposal, threatening the environment with a new kind of plastic pollution. Herein, we investigated the filtration performance of the N95 respirator by specifically analyzing the structure in the key filtration layers of meltblown nonwoven after decontamination with one and five cycles of liquid hydrogen peroxide, ultraviolet radiation, moist heat, and aqueous soap solution treatments. With the aid of X-ray microcomputed tomography (microCT) analysis, the local structural heterogeneity of the meltblown nonwoven has been unfolded and subsequently correlated with their filtration performance at a face velocity that matched with speaking conditions (similar to 3.89 m/s). The filtration efficiency results of the N95 respirator remain unaltered after performing one cycle of treatment modalities (except autoclave). 
650 4 |a Kémiai tudományok 
700 0 1 |a Wang Fang  |e aut 
700 0 1 |a Kumar Shubham  |e aut 
700 0 1 |a Nawal Ruchika R.  |e aut 
700 0 1 |a Kumar Priya  |e aut 
700 0 1 |a Yadav Sudha  |e aut 
700 0 1 |a Szenti Imre  |e aut 
700 0 1 |a Kukovecz Ákos  |e aut 
700 0 1 |a Schiller Ulf D.  |e aut 
700 0 1 |a Rawal Amit  |e aut 
856 4 0 |u http://publicatio.bibl.u-szeged.hu/26514/1/StructuralandfunctionalintegrityofdecontaminatedN95respiratorsExperimentalresults.pdf  |z Dokumentum-elérés