Hydroxyapatite-coated implants provide better fixation in total knee arthroplasty. A meta-analysis of randomized controlled trials.

The potential advantages of hydroxyapatite (HA)-coated cementless total knee arthroplasty (TKA) implants are bone stock preservation and biological fixation. Studies comparing the outcomes of HA-coated cementless, non HA-coated cementless (uncemented) and cemented TKA implants reported contradictory...

Teljes leírás

Elmentve itt :
Bibliográfiai részletek
Szerzők: Horváth Tamara
Hanák Lilla
Hegyi Péter
Butt Edina
Varjú-Solymár Margit
Szűcs Ákos
Varga Orsolya
Thien Bui Quoc
Szakács Zsolt
Csonka Endre
Hartmann Petra
Dokumentumtípus: Cikk
Megjelent: 2020
Sorozat:PLOS ONE 15 No. 5
doi:10.1371/journal.pone.0232378

mtmt:31312042
Online Access:http://publicatio.bibl.u-szeged.hu/19298
LEADER 02977nab a2200325 i 4500
001 publ19298
005 20200804095741.0
008 200804s2020 hu o 0|| zxx d
022 |a 1932-6203 
024 7 |a 10.1371/journal.pone.0232378  |2 doi 
024 7 |a 31312042  |2 mtmt 
040 |a SZTE Publicatio Repozitórium  |b hun 
041 |a zxx 
100 1 |a Horváth Tamara 
245 1 0 |a Hydroxyapatite-coated implants provide better fixation in total knee arthroplasty. A meta-analysis of randomized controlled trials.  |h [elektronikus dokumentum] /  |c  Horváth Tamara 
260 |c 2020 
300 |a Azonosító: e0232378-Terjedelem: 13 p 
490 0 |a PLOS ONE  |v 15 No. 5 
520 3 |a The potential advantages of hydroxyapatite (HA)-coated cementless total knee arthroplasty (TKA) implants are bone stock preservation and biological fixation. Studies comparing the outcomes of HA-coated cementless, non HA-coated cementless (uncemented) and cemented TKA implants reported contradictory data. Our aim was to provide a comparison of the effects of HA coating of tibial stem on the stability and functionality of TKA implants.A systematic literature search was performed using MEDLINE, Scopus, EMBASE and the CENTRAL databases up to May 31st, 2019. The primary outcome was Maximum Total Point Motion (MTPM) of the tibial stem. This parameter is determined by radiosterometric analysis and refers to the migration pattern of the prosthesis stems. The clinical outcomes of the implanted joints were evaluated by the Knee Society Knee Score (KSS) and the Knee Society Function Score (KFS). Weighted mean difference (WMD) with 95% confidence interval (CI) were calculated with the random-effects model.Altogether, 11 randomized controlled trials (RCTs) with 902 patients for primary TKA implants were included. There was a statistically significant difference in the MTPM values with the use of HA-coated and uncoated uncemented implants (WMD = +0.28, CI: +0.01 to +0.56, P<0.001). However, HA-coated stems showed significantly higher migration when compared with the cemented prostheses (WMD = -0.29, CI: -0.41 to -0.16, P<0.001). The KSS values of HA-coated implants were significantly higher than those for the uncemented implants; moreover, KSS and KFS outcome scores were statistically not different between the HA-coated and cemented prosthesis cases.HA-coating yields better stability than other, uncemented prostheses. More importantly, the HA-coating is not outperformed by cemented prosthesis in providing good functional outcome. 
700 0 1 |a Hanák Lilla  |e aut 
700 0 1 |a Hegyi Péter  |e aut 
700 0 1 |a Butt Edina  |e aut 
700 0 2 |a Varjú-Solymár Margit  |e aut 
700 0 2 |a Szűcs Ákos  |e aut 
700 0 2 |a Varga Orsolya  |e aut 
700 0 2 |a Thien Bui Quoc  |e aut 
700 0 2 |a Szakács Zsolt  |e aut 
700 0 2 |a Csonka Endre  |e aut 
700 0 2 |a Hartmann Petra  |e aut 
856 4 0 |u http://publicatio.bibl.u-szeged.hu/19298/1/Horvathetal_2020_Plos_One.pdf  |z Dokumentum-elérés