Determination of volatile metabolite markers using HS-SPME-GC-MS technique = Illékony anyagcseremarkerek meghatározása HS-SPME-GC-MS technikával

In our study, headspace solid-phase microextraction coupled with gas chromatography–mass spectrometry (HS-SPME-GC-MS) technique was used to analyse microbial volatile organic compounds (MVOC’s) of a mushroom disease-related microorganism: Trichoderma aggressivum. Its volatile metabolite markers were...

Teljes leírás

Elmentve itt :
Bibliográfiai részletek
Szerzők: Juhász Loretta
Radványi Dalma
Jókai Zsuzsa
Fodor Péter
Testületi szerző: International Symposium on Analytical and Environmental Problems (21.) (2015) (Szeged)
Dokumentumtípus: Könyv része
Megjelent: 2015
Sorozat:Proceedings of the International Symposium on Analytical and Environmental Problems 21
Kulcsszavak:Kémia
Online Access:http://acta.bibl.u-szeged.hu/56010
LEADER 01909naa a2200241 i 4500
001 acta56010
005 20220808154742.0
008 181210s2015 hu o 1|| zxx d
020 |a 978-963-306-411-5 
040 |a SZTE Egyetemi Kiadványok Repozitórium  |b hun 
041 |a zxx 
100 1 |a Juhász Loretta 
245 1 0 |a Determination of volatile metabolite markers using HS-SPME-GC-MS technique = Illékony anyagcseremarkerek meghatározása HS-SPME-GC-MS technikával  |h [elektronikus dokumentum] /  |c  Juhász Loretta 
260 |c 2015 
300 |a 396-400 
490 0 |a Proceedings of the International Symposium on Analytical and Environmental Problems  |v 21 
520 3 |a In our study, headspace solid-phase microextraction coupled with gas chromatography–mass spectrometry (HS-SPME-GC-MS) technique was used to analyse microbial volatile organic compounds (MVOC’s) of a mushroom disease-related microorganism: Trichoderma aggressivum. Its volatile metabolite markers were monitored and then identified. To make reliable identification results, different manual correction steps were implemented into the evaluation process (depending on the compound intensity or on the rate of compound coelucion). Identification steps were the follows: background subtraction then manual deconvolution. In some cases, compounds’ molecular ion appeared on the mass spectra, which molecular ion’s m/z value was also used for the identification. Moreover retention index (RI) of the evaluated compound was also calculated then compared to the RI values found in the literature and WebBooks. 
695 |a Kémia 
700 0 1 |a Radványi Dalma  |e aut 
700 0 1 |a Jókai Zsuzsa  |e aut 
700 0 1 |a Fodor Péter  |e aut 
710 |a International Symposium on Analytical and Environmental Problems (21.) (2015) (Szeged) 
856 4 0 |u http://acta.bibl.u-szeged.hu/56010/1/proceedings_of_isaep_2015_396-400.pdf  |z Dokumentum-elérés